Loopy Orthogonal Signal Correction Scatter Correction in Non-Invasive Blood Glucose
Koreksi Pencaran Loopy Orthogonal Signal Correction pada Glukosa Darah Non-Invasif
DOI:
https://doi.org/10.29244/ijsa.v7i2p105-113Keywords:
loopy OSC, non-invasive, orthogonal signal correction, scatter correction, spectroscopyAbstract
Spectroscopy is the study of matter based on light, sound, or particles emitted, absorbed, or reflected as well as the study of methods for generating and analyzing spectra. The spectrum has systematic diversity, namely the presence of light scattering and differences in the size of objects. The spectroscopic output allows for scattering shifts, because the same object measured several times does not exactly produce the same spectrum. Problems found in the spectrum can be overcome by pre-processing the data, namely the scatter correction method. Scatter correction is used to reduce the physical properties in the spectrum so that the information obtained is relatively the same for each spectrum, produces good estimates, and can be interpreted well. One of the spectroscopic tools that utilize infrared light is a non-invasive blood glucose level measuring device. The output of the tool is the time domain and intensity spectrum. Each object from the resulting spectrum still has noise, so scatter correction can be applied to this data. The purpose of this study was to perform a loopy Orthogonal Signal Correction (OSC) scatter correction method on time domain spectrum data on intensity on a non-invasive blood glucose level measuring device. The OSC method uses the concept of orthogonality to the mean by drawing the intensity value, weighting it, calculating the vector loading and then making corrections to the initial intensity. Based on the analysis, the loopy OSC method is better than OSC because the convergence is more accurate, the mean difference is smaller, the variance is smaller and the value converges on all the values tested. Based on exploration and the average difference, the loopy OSC method is better able to form the same pattern for each replication. This also shows that an object that is measured repeatedly has been able to be identified as the same object.
Downloads
References
Arnita, A., & Sutarman, S. (2011). Membanding Metode Multiplicative Scatter Correction (MSC) dan Standard Normal Variate (SNV) pada Model Kalibrasi Peubah Ganda. Bulletin of Mathematics, 3(01), 25–38.
Aulia, W. (2017). Koreksi Pencaran pada Data Hasil Pengukuran Alat Pemantau Kadar Glukosa Darah Non-Invasif.
Barnes, R. J., Dhanoa, M. S., & Lister, S. J. (1989). Standard normal variate transformation and de-trending of near-infrared diffuse reflectance spectra. Applied Spectroscopy, 43(5), 772–777.
Blanco, M., Coello, J., Montoliu, I., & Romero, M. A. (2001). Orthogonal signal correction in near infrared calibration. Analytica Chimica Acta, 434(1), 125–132.
Budiastra, I. W., & Seminar, K. B. (2014). Pengembangan Metode Pengukuran Nondestruktif untuk Menentukan Mutu dan Fermentasi Biji Kakao Utuh Menggunakan NIR Spectroscopy.
Hai-bin, Q., Dan-lin, O., & Yi-yu, C. (2005). Background correction in near-infrared spectra of plant extracts by orthogonal signal correction. Journal of Zhejiang University Science B, 6, 838–843.
Iqbal, Z. (2015). Pendugaan Kandungan Kimia Tandan Buah Segar (TBS) Kelapa Sawit Menggunakan Spektroskopi NIR.
Isaksson, T., & Næs, T. (1988). The effect of multiplicative scatter correction (MSC) and linearity improvement in NIR spectroscopy. Applied Spectroscopy, 42(7), 1273–1284.
Laref, R., Ahmadou, D., Losson, E., & Siadat, M. (2017). Orthogonal signal correction to improve stability regression model in gas sensor systems. Journal of Sensors, 2017.
Raudlah, S. (2018). Perbandingan Metode Koreksi Pencaran pada Data Hasil Alat Pengukur Kadar Glukosa Darah Non-Invasif.
Rinnan, Å., Van Den Berg, F., & Engelsen, S. B. (2009). Review of the most common pre-processing techniques for near-infrared spectra. TrAC Trends in Analytical Chemistry, 28(10), 1201–1222.
Sinaga, Y. (2019). Penerapan Metode Loopy Multiplicative Scatter Correction Dan Orthogonal Signal Correction Pada Spektrum Keluaran Alat Non-Invasif.
Windig, W., Shaver, J., & Bro, R. (2008). Loopy MSC: a simple way to improve multiplicative scatter correction. Applied Spectroscopy, 62(10), 1153–1159.
Wold, S., Antti, H., Lindgren, F., & Öhman, J. (1998). Orthogonal signal correction of near-infrared spectra. Chemometrics and Intelligent Laboratory Systems, 44(1–2), 175–185.
WR, H. (1987). Data analysis: wavelength selection method. Near-Infrared Technology in the Agricultural and Food Industries, 35–55.